Psion OMNII Manual de usuario Pagina 265

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 358
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 264
Psion Teklogix Omnii XT10 Hand-Held Computer User Manual C-25
Appendix C: Bar Code Settings
Decoded (Intermec ISCP)
Decoded (ISCP) Options
If Code 128 Emulation is set to off, the Micro PDF-417 symbols are transmitted with one of
the following prefixes:
]L3 if the first codeword is 903-907, 912, 914, 915
]L4 if the first codeword is 908 or 909
]L5 if the first codeword is 910 or 911
Length Restriction
Refer to “Length Restriction” on page C-14 for details.
Add/Remove Data
Refer to “Add/Remove Data” on page C-14 for details.
C.3 Decoded (Intermec ISCP)
Tap on the Scanner drop-down menu, and choose Decoded (Intermec ISCP).
C.3.1 Decoded (ISCP) Options
Laser On Time
The value assigned to this parameter determines how long the laser will remain on when the
scan button or trigger is pressed.
Double-tapping on this parameter displays a dialog box in which you can enter a value
between 1 and 10 seconds.
Vista de pagina 264
1 2 ... 260 261 262 263 264 265 266 267 268 269 270 ... 357 358

Comentarios a estos manuales

Sin comentarios